---
product_id: 611330246
title: "Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger"
brand: "extech"
price: "9038 DH"
currency: MAD
in_stock: true
reviews_count: 5
category: "Extech"
url: https://www.desertcart.ma/products/611330246-extech-dl160-dual-input-true-rms-ac-voltage-current-datalogger
store_origin: MA
region: Morocco
---

# Dual True RMS AC inputs 256,000 readings memory USB PC interface Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger

**Brand:** extech
**Price:** 9038 DH
**Availability:** ✅ In Stock

## Summary

> ⚡ Power Your Precision: Dual-Input Data Logging for the Modern Pro

## Quick Answers

- **What is this?** Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger by extech
- **How much does it cost?** 9038 DH with free shipping
- **Is it available?** Yes, in stock and ready to ship
- **Where can I buy it?** [www.desertcart.ma](https://www.desertcart.ma/products/611330246-extech-dl160-dual-input-true-rms-ac-voltage-current-datalogger)

## Best For

- extech enthusiasts

## Why This Product

- Trusted extech brand quality
- Free international shipping included
- Worldwide delivery with tracking
- 15-day hassle-free returns

## Key Features

- • **Intuitive LCD Display:** Stay informed with real-time time/date, current readings, and Min/Max values directly on the clear LCD screen.
- • **Massive Data Capacity:** Log up to 256,000 precise AC voltage/current readings with customizable sampling intervals from 1 second to 24 hours.
- • **Seamless Data Transfer:** Effortlessly download and analyze your data on PC via USB with included software or export to spreadsheets for advanced insights.
- • **Dual Channel Versatility:** Simultaneously monitor two AC voltage inputs, two AC current inputs, or one of each for comprehensive diagnostics.
- • **Complete Professional Kit:** Includes 2 current clamps, test leads, alligator clips, USB cable, software, universal AC adapter, and batteries—ready for any job.

## Overview

The Extech DL160 is a professional-grade dual input True RMS AC voltage/current datalogger designed for high-precision electrical diagnostics. It supports up to 256,000 logged readings with user-programmable sampling rates, simultaneous dual-channel measurement, and easy USB data transfer to PC. Equipped with a clear LCD, multiple recording modes, and a comprehensive accessory kit, it’s engineered for managers and technicians who demand reliable, detailed electrical data on the go.

## Description

The DL160 is a Dual Input True RMS AC Voltage/Current Data logger. Simultaneously data log 2 channels of up to 256,000 readings of TRMS AC Voltage (600V) or Current (200A) or one AC Voltage and one AC Current input with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, and min/max. Readings can be downloaded to your PC via the USB interface. Featuring Normal, Peak, and Capture (user specified trigger level) recording modes. Complete with 2 current clamps, two sets of test leads, 2 sets of alligator clips, software, USB cable, Universal AC Adapter, and 4 x AAA and 2 x CR2032 Batteries.

Review: Buy a Fluke - Software terrible. Switches itself off randomly
Review: Schnelle Lieferung - Artikel Beschreibung ist gut

## Features

- Datalog up to 256,000 readings with user programmable sample rate
- Simultaneously measure two AC voltage inputs or two AC current inputs or one AC voltage and one AC current input
- Readings can be downloaded to your PC via the USB interface and analyzed using the included software or exported to a spreadsheet
- LCD indicates time/date, current readings and Min/Max
- Auto Power off and battery check

## Technical Specifications

| Specification | Value |
|---------------|-------|
| ASIN | B004OSHVQK |
| Brand | Extech |
| Brand Name | Extech |
| Color | green |
| Colour | green |
| Compatible Devices | PC with USB port and included software, standard AC power source |
| Customer Reviews | 4.2 out of 5 stars 54 Reviews |
| Global Trade Identification Number | 00793950471609 |
| Item Dimensions | 6.3 x 3.3 x 11.4 centimeters |
| Item Highlight | Two AC voltage or current inputs, True RMS, 100000-reading memory, USB software, clamps, SD card, case |
| Item Weight | 0.25 Kilograms |
| Item dimensions L x W x H | 6.3 x 3.3 x 11.4 centimeters |
| Item weight | 0.25 Kilograms |
| Manufacturer | Extech |
| Measurement Type | Voltmeter or Ammeter |
| Minimum Operating Voltage | 10 Volts (AC) |
| Model | DL160 |
| Number of Items | 1 |
| Part Number | DL160 |
| Power Source | Corded Electric |
| Power source | Corded Electric |
| Specification Met | CE |
| Style | Dual Input True RMS AC Voltage/Current Datalogger |
| Style Name | Dual Input True RMS AC Voltage/Current Datalogger |
| UPC | 707223199725 793950471609 |
| Unit Count | 1 Count |
| Upper Temperature Rating | 300 Degrees Celsius |

## Images

![Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger - Image 1](https://m.media-amazon.com/images/I/61YXyuDU+GL.jpg)
![Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger - Image 2](https://m.media-amazon.com/images/I/61Wb8Mp-OiL.jpg)
![Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger - Image 3](https://m.media-amazon.com/images/I/61mhq-7zurL.jpg)
![Extech DL160 Dual Input True RMS AC Voltage/Current Datalogger - Image 4](https://m.media-amazon.com/images/I/619G9o51FrL.jpg)

## Available Options

This product comes in different **Style** options.

## Questions & Answers

**Q: how does it measure current? is there cts'? aslo can it be installed without de-energizing the load?**
A: There are current clamps for every leg as well as gator clip probes for every leg N and ground (I think there is also a current clamp for N but I don't have it in front of me.) There is no problem hooking it all up live as long as you are careful. I've never had a problem.

**Q: Does it comes with wi-fi capabilities for remote data analysis?**
A: No, it does not have that capability.

**Q: will it work with linux?**
A: Hi, thanks for your question, Unfortunately, the software is only available and has been tested for windows 7,8,10, and 11. if you have any questions, feel free to contact our technical support line at 866-477-3687 option 3

**Q: What is the maximum wire diameter the current clamp will fit on?**
A: While I cannot say for sure what the maximum wire size is that the current clamp would fit on, it will certainly fit on any wire sized per NEC to carry the allowable amperage that the DL 160 is max rated to measure. Any larger wire sizes would most likely be in an installation subject to more amps than that max rating, possibly damaging the device(s) if deployed to same. Only exception I can think of is where the allowable amps would be within limits and still encounter a larger than normal but then also a much longer wire would be in use to allow for voltage drop.

## Customer Reviews

### ⭐ Buy a Fluke
*by R***R on 28 August 2023*

Software terrible. Switches itself off randomly

### ⭐⭐⭐⭐⭐ Schnelle Lieferung
*by A***E on 23 July 2025*

Artikel Beschreibung ist gut

### ⭐⭐⭐⭐⭐ Extech DL160 Dual Input True RMS Great product!
*by S***. on 3 June 2023*

I want to say first, the people that complained about this meter being made of cheap plastic, need to compare it to most testing instruments. The quality of the plastic used is of the same quality of any other. The only thing they could have done better is to install a silicon type cover for shock protection. The fact is, you should take care of any kind of quality instrument. Wake up and stop griping. You only make yourself sound ignorant. With that said, the reason I purchased this instrument, was to show my electrical provider that it was there incoming power to my home that was causing the issue with power surges, not my end. There linemen came out and did a quick check of the pole and a load test at my meter base and it showed good. After receiving the Extech DL160, I took my readings at the input lines of my main disconnect directly after my meter base. It showed no issue across L1 and L2, but when tested from the neutral to L1 and L2 it showed an issue. Large 30 plus volt spikes. Narrowed it down to the neutral as expected. I was able to get the printouts from the meter to the power companies’s engineer, and he set out a crew right away. After some time redoing wire clamps and almost giving up, they found the neutral on the transformer lose. Without this meter, I would probably still be fighting the power company to fix there problem. I don’t know if I’ll ever use this meter again, but it was well worth the money to save my own electronics, etc in my home and the satisfaction of proving to the power company it was there side causing the problem. (-: Lol

## Frequently Bought Together

- Extech 382100 1200A 3-Phase Power Analyzer/Datalogger
- Brady Authentic (M21-1500-427) Self-Laminating Wire Wrap for Control and Electrical Panels, Datacom Cables, Black on White- For M210, M210-LAB, M211, BMP21-PLUS and BMP21-LAB Printers, 1.5" W 14' L

---

## Why Shop on Desertcart?

- 🛒 **Trusted by 1.3+ Million Shoppers** — Serving international shoppers since 2016
- 🌍 **Shop Globally** — Access 737+ million products across 21 categories
- 💰 **No Hidden Fees** — All customs, duties, and taxes included in the price
- 🔄 **15-Day Free Returns** — Hassle-free returns (30 days for PRO members)
- 🔒 **Secure Payments** — Trusted payment options with buyer protection
- ⭐ **TrustPilot Rated 4.5/5** — Based on 8,000+ happy customer reviews

**Shop now:** [https://www.desertcart.ma/products/611330246-extech-dl160-dual-input-true-rms-ac-voltage-current-datalogger](https://www.desertcart.ma/products/611330246-extech-dl160-dual-input-true-rms-ac-voltage-current-datalogger)

---

*Product available on Desertcart Morocco*
*Store origin: MA*
*Last updated: 2026-09-21*