⏰ Don't let time slip away - Control it with precision!
The GEYADelay Off Single Function Time Relay is a high-performance electronic timer designed for versatile applications. With a compact size of just 18mm, it offers two operational modes (Delay ON and Delay OFF) and supports a wide voltage range of AC/DC 12-240V. The intuitive panel knob allows for easy delay adjustments from 0.1 seconds to 10 days, making it perfect for both professional and personal use. Its LED status indicator ensures you are always aware of the relay's operation, while the CE certification guarantees safety and reliability.
Contact Current Rating | 16 Amps |
Maximum Switching Current | 16 Amps |
Maximum Switching Voltage | 240 Volts |
Operating Time | 1E+1 Hours |
Number of Terminals | 2 |
Operation Mode | Automatic |
Wattage | 5E+2 |
Coil Voltage | 12 Volts |
Contact Type | Spdt |
Current Rating | 16 Amps |
Mounting Type | din_rail |
Specification Met | CE |
A**R
Input Voltage
Relay works as described except for the input voltage.It requires a neutral on one leg of the input or it will fry the timing circuit.The description says it will use up to 240vac but should read 230v for the European voltage levels with a neutral.
G**Y
Pay attention to the timing diagram
This is a useful little smart relay.But, one gotcha that I didn't catch - the relay fires a cycle on power-up. I thought it was only on assertion of the S signal, but it does happen at power up also.And one other minor complaint - there's a high-pitched tone from this when operating off of 12V. Sounds like a switching power supply.
R**R
worked as needed
worked great , easy to install .
N**K
Power Cycle
Great little relay. Fyi when the power is cycled to the relay (not talking trigger power) it will activate. I used mine for strobes so its fine. But if used in a more sensitive situation just be mindful.
G**S
NOT a Delay-OFF Timer
NOT a Delay-OFF timer. This does NOT have a true Delay-OFF timer function. It is an Interval timer as the contacts switch state immediately after power is applied, starting the initial time interval WITHOUT any signal provided. It will then switch contacts back to original state after the initial automatic interval times out. This can be very DANGEROUS if trying to control equipment. Subsequent application of the Signal line will cause contacts to change state. Thereafter when Signal is removed, the time interval restarts and the contacts will return to original state at the end of the time interval.NOTE: Model GRT6-Mxx DOES have a true Delay-Off function.
Trustpilot
2 months ago